Mfg Part Number: UPL-111-1REC4-62-453
Alternate P/N: UPL1111REC462453
NSN : 5925-01-377-8516
NIIN : 013778516
CAGE Code : 12175
Manufacturer: Unitron Industries Inc
Item Name : Circuit Breaker
FSC : 5925 Circuit Breakers
In our inventory, we have more than two billion new and obsolete NSN part like UPL-111-1REC4-62-453. Aviation Sphere can offer an impressive selection of NSN parts. This includes parts like UPL-111-1REC4-62-453 Circuit Breaker from manufacturer Unitron Industries Inc and many more, all of which are available with short lead times and competitive prices. For parts not in our inventory, our dedicated account managers can help you track them down through our international supply chain network that extends across the United States, Canada, and the United Kingdom. Furthermore, Aviation Sphere is an AS9120B, ISO 9001:2015, and FAA AC 0056B accredited business, as well as the only independent distributor with a strict No China Sourcing Pledge, allowing us to ensure that each part part like UPL-111-1REC4-62-453, you purchase from us is fully traceable or comes directly from its manufacturer.
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN part like UPL-111-1REC4-62-453. This means you can quickly sort through National Stock Numbers such as 5925013778516 and find parts from quality manufacturers like Unitron Industries Inc and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-377-8516 Item Description: Circuit Breaker | 5925 | 013778516 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Upl-111-1rec4-62-453 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 10.0 AC AND 4.0 DC |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.062 INCHES NOMINAL |
CRTK | SWITCH TERMINAL TYPE | TAB, SOLDER LUG |
APNQ | III ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
ADAQ | BODY LENGTH | 2.500 INCHES NOMINAL |
AKPX | POLE QUANTITY | 3 |
PKWT | III UNPACKAGED UNIT WEIGHT | 9.500 OUNCES |
CMLP | THREAD QUANTITY PER INCH | 32 |
AFJN | III FRAGILITY FACTOR | MODERATELY RUGGED |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.750 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
ADAT | BODY WIDTH | 2.250 INCHES NOMINAL |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 45.0 AMPERES AC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.870 INCHES MINIMUM AND 1.990 INCHES MAXIMUM |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC AND 30.0 DC |
CPRQ | RESET METHOD | MANUAL |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.750 INCHES NOMINAL |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | III SPECIAL HANDLING FEATURE | MAGNETIC |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 THREADED HOLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
AJEC | BOSS HEIGHT | 0.140 INCHES NOMINAL |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 6 THREADED STUD |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT AND 200.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | INTERNAL AT POLE THREE |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.530 INCHES NOMINAL |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote