Mfg Part Number: 984882-5B
Alternate P/N: 9848825B
NSN : 5950-01-339-8204
NIIN : 013398204
CAGE Code : 95266
Manufacturer: Oeco Corporation
Item Name : Transformer Assembl
In our inventory, we have more than two billion new and obsolete NSN part like 984882-5B. Aviation Sphere can offer an impressive selection of NSN parts. This includes parts like 984882-5B Transformer Assembl from manufacturer Oeco Corporation and many more, all of which are available with short lead times and competitive prices. For parts not in our inventory, our dedicated account managers can help you track them down through our international supply chain network that extends across the United States, Canada, and the United Kingdom. Furthermore, Aviation Sphere is an AS9120B, ISO 9001:2015, and FAA AC 0056B accredited business, as well as the only independent distributor with a strict No China Sourcing Pledge, allowing us to ensure that each part part like 984882-5B, you purchase from us is fully traceable or comes directly from its manufacturer.
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN part like 984882-5B. This means you can quickly sort through National Stock Numbers such as 5950013398204 and find parts from quality manufacturers like Oeco Corporation and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-339-8204 Item Description: Transformer Assembl | 5950 | 013398204 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
984882-5b | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 6.030 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 3.570 INCHES MAXIMUM |
ABTB | MOUNTING HOLE DIAMETER | 0.500 INCHES NOMINAL 2ND GROUP |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ NOMINAL ALL COMPONENTS |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 3RD COMPONENT AND INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL 3RD COMPONENT |
ADAT | BODY WIDTH | 3.440 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 4.500 INCHES NOMINAL 1ST MOUNTING FACILITY SINGLE CENTER GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 3RD SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 1ST COMPONENT AND 4 SECONDARY 1ST COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 3RD COMPONENT AND 3 SECONDARY 3RD COMPONENT |
CBBL | FEATURES PROVIDED | W/RECTIFIER |
CRBZ | WINDING OPERATING CURRENT | 0.01 AMPERES AC NOMINAL 3RD COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.2 AMPERES DC NOMINAL 3RD COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 3.0 AMPERES AC NOMINAL 2ND COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 35.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT 3RD SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.200 1ST COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.280 2ND COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 12.000 2ND COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 18.03 VOLTS-AMPERES 2ND COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 300.5 VOLTS-AMPERES 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 130.00 DC VOLTS MINIMUM 3RD COMPONENT 2ND SECONDARY AND 137.00 DC VOLTS MAXIMUM 3RD COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 14.14 AC VOLTS NOMINAL 2ND COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 16.26 AC VOLTS NOMINAL 3RD COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 178.16 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY AND 195.84 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY AND 213.57 AC VOLTS NOMINAL 3RD COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.01 AC VOLTS NOMINAL 2ND COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 6.01 AC VOLTS NOMINAL 2ND COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 70.70 AC VOLTS NOMINAL 2ND COMPONENT 2ND SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AKPV | MOUNTING FACILITY QUANTITY | 2 2ND GROUP |
AXGY | MOUNTING METHOD | SLOT 1ST GROUP |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 106.05 AC VOLTS NOMINAL 1ST COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 15.55 AC VOLTS NOMINAL 1ST COMPONENT 2ND SECONDARY |
AFHM | MOUNTING TAB WIDTH | 0.625 INCHES NOMINAL |
BKPL | RATING METHOD | ELECTRICAL 2ND COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES AC NOMINAL 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 0.2 VOLTS-AMPERES 3RD COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 160.2 VOLTS-AMPERES 3RD COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 5245.8 VOLTS-AMPERES 2ND COMPONENT 3RD SECONDARY |
ABTD | MOUNTING SLOT WIDTH | 0.187 INCHES NOMINAL 1ST GROUP |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL 2ND COMPONENT |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.500 INCHES NOMINAL 2ND MOUNTING FACILITY SINGLE CENTER GROUP |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 5.375 INCHES NOMINAL 3RD MOUNTING FACILITY SINGLE CENTER GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 2 1ST GROUP |
AXGY | MOUNTING METHOD | TAB 3RD GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE 2ND GROUP |
BKPL | RATING METHOD | ELECTRICAL 1ST COMPONENT 4TH SECONDARY |
BKPL | RATING METHOD | ELECTRICAL ALL COMPONENTS 1ST SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY 2ND COMPONENT AND 4 SECONDARY 2ND COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 0.035 AMPERES AC NOMINAL 3RD COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 50.0 MILLIAMPERES AC NOMINAL 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.040 3RD COMPONENT SINGLE PRIMARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.060 1ST COMPONENT 2ND SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.090 2ND COMPONENT 4TH SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 0.100 3RD COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 1.200 2ND COMPONENT 1ST SECONDARY |
CRGS | DC RESISTANCE RATING IN OHMS | 2.750 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 159.07 VOLTS-AMPERES 1ST COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 3535.0 VOLTS-AMPERES 2ND COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 7.47 VOLTS-AMPERES 3RD COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 149.88 AC VOLTS NOMINAL 2ND COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 15.55 AC VOLTS NOMINAL 3RD COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 530.25 AC VOLTS NOMINAL 1ST COMPONENT 4TH SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 36 WIRE LEAD |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote