Mfg Part Number: P-3526
Alternate P/N: P3526
NSN : 5950-00-615-9253
NIIN : 006159253
CAGE Code : 15815
Manufacturer: Geotronic Labs Inc
Item Name : Transformer Power
In our inventory, we have more than two billion new and obsolete NSN part like P-3526. Aviation Sphere can offer an impressive selection of NSN parts. This includes parts like P-3526 Transformer Power from manufacturer Geotronic Labs Inc and many more, all of which are available with short lead times and competitive prices. For parts not in our inventory, our dedicated account managers can help you track them down through our international supply chain network that extends across the United States, Canada, and the United Kingdom. Furthermore, Aviation Sphere is an AS9120B, ISO 9001:2015, and FAA AC 0056B accredited business, as well as the only independent distributor with a strict No China Sourcing Pledge, allowing us to ensure that each part part like P-3526, you purchase from us is fully traceable or comes directly from its manufacturer.
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN part like P-3526. This means you can quickly sort through National Stock Numbers such as 5950006159253 and find parts from quality manufacturers like Geotronic Labs Inc and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-615-9253 Item Description: Transformer Power | 5950 | 006159253 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
P-3526 | C | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.219 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.281 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 3.594 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 3.656 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.202 INCHES MINIMUM SINGLE GROUP AND 0.208 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 5.032 INCHES MINIMUM AND 5.094 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.032 INCHES MINIMUM AND 3.094 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.594 INCHES MINIMUM AND 2.656 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
CBBL | FEATURES PROVIDED | W/SWITCH |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.43 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 20.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 660.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 0.1 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 126.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 165.0 VOLTS-AMPERES SINGLE COMPONENT SINGLE PRIMARY |
CRMJ | WINDING POWER RATING | 2.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 34.3 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 52.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 99.60 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING AND FIVE SECONDARY WINDINGS; FIFTH SECONDARY CENTER TAPPED |
TTQY | TERMINAL TYPE AND QUANTITY | 19 WIRE LEAD |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote