Mfg Part Number: 130-029-1
Alternate P/N: 1300291
NSN : 5950-00-549-1969
NIIN : 005491969
CAGE Code : 15815
Manufacturer: Geotronic Labs Inc
Item Name : Transformer Power
In our inventory, we have more than two billion new and obsolete NSN part like 130-029-1. Aviation Sphere can offer an impressive selection of NSN parts. This includes parts like 130-029-1 Transformer Power from manufacturer Geotronic Labs Inc and many more, all of which are available with short lead times and competitive prices. For parts not in our inventory, our dedicated account managers can help you track them down through our international supply chain network that extends across the United States, Canada, and the United Kingdom. Furthermore, Aviation Sphere is an AS9120B, ISO 9001:2015, and FAA AC 0056B accredited business, as well as the only independent distributor with a strict No China Sourcing Pledge, allowing us to ensure that each part part like 130-029-1, you purchase from us is fully traceable or comes directly from its manufacturer.
Our website offers a number of parametric search capabilities, one of which allows you to search specifically for NSN part like 130-029-1. This means you can quickly sort through National Stock Numbers such as 5950005491969 and find parts from quality manufacturers like Geotronic Labs Inc and many others. To begin the purchasing process immediately, submit an RFQ today. Our team of dedicated account managers is standing by and will respond to all inquiries in 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-549-1969 Item Description: Transformer Power | 5950 | 005491969 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
130-029-1 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
CRMJ | WINDING POWER RATING | 2.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY17.16 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 26.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY99.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 5.00 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 99.60 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY115.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | 2 PRIMARY WINDINGS; 5 SECONDARY WINDINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHEDNOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.031 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP5.031 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.571 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP4.571 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.202 INCHES MINIMUM SINGLE GROUP AND 0.202 INCHES MINIMUM SINGLE GROUP AND 0.208 INCHES MAXIMUM SINGLE GROUP0.208 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENTSINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 6.000 INCHES MAXIMUM6.000 INCHES MAXIMUM |
ADAT | BODY WIDTH | 3.938 INCHES MAXIMUM3.938 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 3.375 INCHES MAXIMUM3.375 INCHES MAXIMUM |
AKNA | INCLOSURE TYPE | FULLY INCLOSEDFULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP4 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUPUNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT5 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.1 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 20.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 200.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 660.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 0.1 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY2.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CRMJ | WINDING POWER RATING | 126.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 17.16 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY126.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |